[CONTROL PANEL INSTRUMENTS].  An event indicator that would give a gray or "barber pole" indicator flag on the results of certain control panel actions.  Over 30 of these were in the Command Module -- A circular dual indicator meter with the left meter measuring the difference in pressure between spacesuits and cabin in inches H20 + or - 5.  The right meter measures the total rate of flow of oxygen supplied to the environmental control system downstream of the main regulator valve in LB/HR [pounds per hour] from 0.2 to 1.0 -- A rectangular dual indicator meter that measured pressure of the service module cryogenic hydrogen tanks with a measurement range from 0 to over 300 PSIA.  The unit came from the Command Module ground trainer used by astronauts in Houston, Texas.  All were made by Weston Instruments, Inc.	 (3)
[CONTROL PANEL INSTRUMENTS]. An event indicator that would give a gray or "barber pole" indicator flag on the results of certain control panel actions. Over 30 of these were in the Command Module -- A circular dual indicator meter with the left meter measuring the difference in pressure between spacesuits and cabin in inches H20 + or - 5. The right meter measures the total rate of flow of oxygen supplied to the environmental control system downstream of the main regulator valve in LB/HR [pounds per hour] from 0.2 to 1.0 -- A rectangular dual indicator meter that measured pressure of the service module cryogenic hydrogen tanks with a measurement range from 0 to over 300 PSIA. The unit came from the Command Module ground trainer used by astronauts in Houston, Texas. All were made by Weston Instruments, Inc. (3)

Details
[CONTROL PANEL INSTRUMENTS]. An event indicator that would give a gray or "barber pole" indicator flag on the results of certain control panel actions. Over 30 of these were in the Command Module -- A circular dual indicator meter with the left meter measuring the difference in pressure between spacesuits and cabin in inches H20 + or - 5. The right meter measures the total rate of flow of oxygen supplied to the environmental control system downstream of the main regulator valve in LB/HR [pounds per hour] from 0.2 to 1.0 -- A rectangular dual indicator meter that measured pressure of the service module cryogenic hydrogen tanks with a measurement range from 0 to over 300 PSIA. The unit came from the Command Module ground trainer used by astronauts in Houston, Texas. All were made by Weston Instruments, Inc. (3)

More from Space Exploration

View All
View All